NAUTILUS® DELTA™ Tip Confirmation System (TCS)

The NAUTILUS® DELTA™ TCS provides real-time catheter tip location information by using the patient’s cardiac electrical activity and is indicated for use as an alternative method to chest X-ray and fluoroscopy for CVAD tip placement confirmation in patient’s with an identifiable P-wave.

Healthcare Professional Downloads:

Request Information Customer Service
1-800-321-4254

Features:

  • USER FRIENDLY – Large swiveling display and graphic interface facilitates waveform interpretation from multiple viewing angles
  • PORTABLE – Netbook with carrying handle, lightweight patient module and connection cables enables movement between procedure rooms
  • STREAMLINED – No additional wire or stylet is needed to track the port catheter
  • STERILE – Proprietary through-drape connection from NAUTILUS DELTA® E Electrical Adaptor to Patient Module
  • ESTABLISHED – Intracavitary ECG method for has been used for over 30 years for catheter tip confirmation and is the subject of multiple peer-reviewed publications**

NAUTILUS® DELTA™ Tip Confirmation System (TCS) for Port Placements

Elevate your port practice with ECG-based Tip Confirmation!

The NAUTILUS® DELTA™ TCS is indicated for navigation and positioning of central venous access devices (CVADs) of at least 3 Fr in size. The NAUTILUS® DELTA™ TCS provides real-time catheter tip location information by using the patient’s cardiac electrical activity and is indicated for use as an alternative method to chest X-ray and fluoroscopy for CVAD tip placement confirmation in patient’s with an identifiable P-wave.

bccvpkkmuxywle72a4i6vknbwko1axcx.jpg

h62l7rg3qdt8bxtkcmlzv4biuccgynmp.jpg

r754sitwh68akxxyzjeu269eepa9blew.jpg

zfnreuv5sy42uetd6ykabjj8e5464xih.jpg

bccvpkkmuxywle72a4i6vknbwko1axcx.jpg
h62l7rg3qdt8bxtkcmlzv4biuccgynmp.jpg
r754sitwh68akxxyzjeu269eepa9blew.jpg
zfnreuv5sy42uetd6ykabjj8e5464xih.jpg

Specifications

Product Item IDProduct Item NamePOWERPORT® DescriptionSuture MechanismCatheterTray
9770323NAUTILUS® DELTA™ Tip Confirmation System (Includes: Netbook with Pre-loaded Software, Patient Module, and ECG Cable)----
1606382NAUTILUS® DELTA™ Tip Confirmation System Port Kit (with NAUTILUS DELTA™ E Electrical Adaptor*)CLEARVUE® ispSilicone Overmold6F CHRONOFLEX™Intermediate
1608382NAUTILUS® DELTA™ Tip Confirmation System Port Kit (with NAUTILUS DELTA™ E Electrical Adaptor*)CLEARVUE® ispSilicone Overmold8F CHRONOFLEX™Intermediate
1616380NAUTILUS® DELTA™ Tip Confirmation System Port Kit (with NAUTILUS DELTA™ E Electrical Adaptor*)CLEARVUE® SlimSilicone Suture Plugs6F CHRONOFLEX™Intermediate
1618380NAUTILUS® DELTA™ Tip Confirmation System Port Kit (with NAUTILUS DELTA™ E Electrical Adaptor*)CLEARVUE® SlimSilicone Suture Plugs8F CHRONOFLEX™Intermediate
1808380NAUTILUS® DELTA™ Tip Confirmation System Port Kit (with NAUTILUS DELTA™ E Electrical Adaptor*)M.R.I.® ispSilicone Suture Plugs8F CHRONOFLEX™Intermediate
1808580NAUTILUS® DELTA™ Tip Confirmation System Port Kit (with NAUTILUS DELTA™ E Electrical Adaptor*)M.R.I.® ispSilicone Suture Plugs8F GROSHONG™Intermediate
1716080NAUTILUS® DELTA™ Tip Confirmation System Port Kit (with NAUTILUS DELTA™ E Electrical Adaptor*)Titanium SlimSilicone Suture Plugs6F CHRONOFLEX™Intermediate

Accessories

9770068

Remote Control

9770084

Brother Printer Paper (20 boxes, 50/box)

9770108

Brother Printer Bracket (for mounting to Rollstand)

9770109

Optional Large RAM Mount for Medical Equipment Rollstand (for Laptop Ultrasound)

9770116

Medical Equipment Rollstand

9770119

Side Mount for Medical Equipment Rollstand

9770324

Dymo Printer Paper (6 rolls, 110 pg/roll)

LW450Turbo

Dymo Printer (adhesive label printer)

MW260MFIC129

Brother Printer (standard printer)

*Please check with your local Bard Sales Representative for updates on stand-alone NAUTILUS® DELTA™ E Electrical Adaptor product availability.

**Data on file at Bard Peripheral Vascular, Inc.

The NAUTILUS® DELTA™ Tip Confirmation System (TCS) is indicated for navigation and positioning of central venous access devices (CVADs) of at least 3 Fr in size. The NAUTILUS DELTA® TCS provides real-time catheter tip location information by using the patient’s cardiac electrical activity and is indicated for use as an alternative method to chest X-ray and fluoroscopy for CVAD tip placement confirmation.

In adult patients and in adolescents (greater than 12 through 21 years of age), the NAUTILUS® DELTA™ TCS can be used with CVADs such as peripherally inserted central catheters (PICCs), central venous catheters (CVCs), implantable ports, and hemodialysis catheters; in children (greater than 2 to 12 years of age), the NAUTILUS® DELTA™ TCS can be used with PICCs and with centrally inserted central catheters (CICCs); in infants (greater than 1 month to 2 years of age) and in neonates (from birth to 1 month of age), the NAUTILUS® DELTA™ TCS can be used with CICCs. In each specific age group, the CVAD type and size must be chosen and the CVAD must be used according to the CVAD’s indications and instructions for use.

Limiting but not contraindicated situations for this method are in patients where alterations of cardiac rhythm change the presentation of the P wave as in atrial fibrillation, atrial flutter, severe tachycardia, and pacemaker driven rhythm. In such patients, who are easily identifiable prior to central venous catheter insertion, the use of an additional method is required to confirm catheter tip location.

1