Skip to main content
Tridyne Vascular Sealant

Tridyne Vascular Sealant
Tridyne™ Vascular Sealant

Clinically proven to perform under pressure1

Healthcare Professional Downloads:

Request Information Customer Service
800-556-6275

A strong elastic seal
where it matters most

Tridyne™ Vascular Sealant is the latest addition to the BD family of hemostasis solutions, offering cardiovascular, cardiothoracic, and vascular surgeons a unique, easy-to-use solution to reinforce aortic anastomoses and control bleeding when adjunctive measures are required. By combining a proprietary formulation of polyethelyne glycol and human serum albumin, it forms a strong, flexible seal, even in anticoagulated patients.1,2 The Tridyne™ hydrogel is designed to adhere where it should – on both tissue and grafts.*

 

Preclinical data demonstrates that Tridyne™ Vascular Sealant resorbs naturally to maintain its seal strength through the critical postoperative period without compromising tissue healing.2

Tridyne Surgical Video

Performance under pressure

In a prospective, randomized, controlled multicenter study, Tridyne™ Vascular Sealant outperformed Gelfoam® Plus Hemostasis Kit in several critical measures. The study included 156 patients from 18 different centers who underwent thoracic aortic surgery, with hemostasis evaluated at the aortic anastomotic suture line.1

PF10765_Tridyne_section-3.jpg

PF10765_Tridyne_section-3.jpg

Clarity and coverage

The specialized Tridyne™ formulation is transparent and forms a completely clear hydrogel at the application site. With its unique combination of clarity and coverage, Tridyne™ Vascular Sealant allows for visual confirmation of hemostasis at the anastomotic suture line—making it an ideal choice for aortic surgery.

PF10765_Tridyne_section2.jpg

PF10765_Tridyne_section2.jpg

The proven solution during aortic repair1

Tridyne™ Vascular Sealant offers surgeons a specialized, easy-to-use solution during aortic repair, with unique application control and clinically proven results.1 With its demonstrated ability to provide fast, effective control of bleeding, it’s clearly the sealant choice for aortic surgery.

PF10765_Tridyne_section-4.jpg

PF10765_Tridyne_section-4.jpg

Precise, controlled application—made easy

Tridyne™ Vascular Sealant provides application control without the need for pressurized gas.

 The Tridyne™ applicator is designed to:

  • Provide uniform, continuous coverage without clumping
  • Control sealant application by varying hand pressure
  • Easily transition from targeted application over the anastomosis to broader coverage to address more diffuse bleeding
PF10765_Tridyne_section1.jpg

PF10765_Tridyne_section1.jpg

BioSurgery Surgical Education

The following pages will introduce you to Bard’s BioSurgical Education modalities and faculty. We are committed to advanced professional education – helping you choose the right products and procedures to provide the right outcomes for your patients.

Selecting a partner for surgical products can be a difficult decision. There is a lot at stake for many people in your organization, including Operating Room Managers, Surgeons, Materials Management and of course your patients. For this reason Bard Davol provides information on our products and product portfolios that help you simplify the selection process and puts pertinent, important information at your finger tips.

Our commitment to your success extends beyond the OR. We also offer access to our Customer Service, Medical Services and Support, Reimbursement Hotline and our world-class Surgeon Education groups. These are resources Bard Davol invests in for your success, staffed by experts who are passionate about offering you the best service and experience possible.

For more information, visit: https://www.crbard.com/en-US/solutions/value-based-healthcare-solutions

 

Specifications

Product Item IDProduct Item NamePackaging (SKU)Dimensions
TDVS004Tridyne™ Vascular Sealant4/cs.Tridyne™ Vascular Sealant (4 mL)
TDST0020Tridyne™ Vascular Sealant10/cs.Tridyne™ Applicator Spray Tips (pack of 2)
TDET0006Tridyne™ Vascular Sealant4/csTridyne™ Extended Spray Tip, 16 cm (6”)

* The use of Tridyne™ Vascular Sealant with ePTFE grafts or vascular patches has not been studied clinically. Preclinical data on file. Preclinical test results may not correlate to clinical performance.

1. Khoynezhad A, DelaRosa J, Moon M, et al. Facilitating Hemostasis After Proximal Aortic Surgery: Results of The PROTECT Trial. Ann Thorac Surg. 2018;105(5):1357-1364.
2. BD Inc. In vitro testing. Data on file. Preclinical test results may not correlate to clinical performance.
3. Tridyne™ Vascular Sealant is indicated for use in aortic surgery when adjunctive measures to achieve hemostasis are required by mechanically sealing areas of leakage.
4. One subject from the Gelfoam® Plus treatment group required a reoperation for aortic bleeding complications following completed surgery through 30 days.
 5. Mean time to hemostasis was 2.07 minutes for the Tridyne™ Vascular Sealant treatment group and 6.3 minutes for the Gelfoam® Plus control treatment group (P < 0.0001).